6. Two polycarbonate plastic tube caps for plugs.
7. High-purity silicone rubber soft tubing (1/800 ID 1/400 OD:
Nine 5 cm long, thirteen 15 cm long, and three 25 cm long).
8. Tygon® 3-stop tubing S3™E-LFL 1.85 mm ID.
9. Surgical instruments: three clamps, six forceps, four metal spa-
tulas, two scissors, and one scalpel handle.
10. Stainless-steel instrument drying tray with rolled bead edge.
11. Two worm-drive clamps for firm hose and tube, steel screw,
1/200 wide band, 2–9/1600 to 3–1/200 clamp ID.
12. Silicone-based lubricant.
2.3
Other Materials
1. Timing belt (700/35T, (3/800) Wide XL).
2. Small pulley: Timing belt pulley, XL series, 0.929“ OD,
10 teeth with “set-screw” for tightening.
3. Large pulley: Timing belt pulley, XL Series, 1.756“ OD with
“set-screw” for tightening.
4. 37D L shaped gear motor bracket.
Fig. 1 CAD model of the double-chamber tracheal bioreactor. The bioreactor body and lid are shown as
translucent. (a) Top view showing the position of the anchors and the trachea between them with a cable tie
on each end for tracheal anchorage; (b) Lateral view showing the position of the motor, pulleys, belt, and shaft
holder on the bioreactor right side
De-Epithelialization of Tracheal Grafts